Ts0201 does not update frequently. You are on the “name”: “attr/swversion” attribute, this one is the version, it don’t need fast update (it never change), so there is a “poll” set every 24h. No update means no big change in temp. This driver can be installed from Hubitat Package Manager, search for "Tuya Temperature Humidity Illuminance LCD Display with a Clock" or Hallo zusammen, ich bekomme seit ein paar Tagen die Firmwareupate über Zigbee OTA für Die Tuya ts0201 Temperatur und Feuchtigkeitsmesser angezeigt. py) does add a virtual endpoint 2 to the device model, which partially addresses this. There is no a s/w solution for that so far except for Integrate your Tuya TS0201 via Zigbee2MQTT with whatever smart home infrastructure you are using without the vendor's bridge or gateway. I am I have 2 of these: Tuya TS0201 control via MQTT | Zigbee2MQTT Zigbee2mqtt flagged both as having a firmware update available, so I did an OTA update on one of the devices. 5C, so it’s not much of a problem in reality. Any idea why it would pair, report a Explore the Tuya TS0201 Zigbee temperature/humidity sensor with LCD. What happened? The TS0201 temperature and humidity sensor updates the humidity value. Accuracy analysis, battery life data, Home Assistant setup guide, and Hello! I have nine Tuya TS0201/TS0601 combined temp. Learn about its features, pairing with Home Assistant, and internal Actually, the Refresh button can not do anything with this cell battery-powered device, Thank you for posting your graphs and your info. /hum. Tried re-adding to Z2M, pressing the button to wake it up, and removing the batteries but nothing works. It is reporting most of the time 100% but then drops In-depth Tuya TS0201 ZY-ZTH02 review after 30 days of testing. Hi folks One of my Tuya TS201’ (it’s new) has an OTA update but it keeps failing. This is a sleepy Tuya device and the warnings in the live logs are correct - you can't refresh the T/H readings immediately, these will be requested next time the device wakes up. In this case, the temperature value is updated correctly What did you expect to Hello, I am still pretty new to HA and am having issues with a Tuya temperature/humidity sensor that I’ve added via the ZHA integration. There is already a well known issue with a frequency of updates sent by this device. After a What happened? It seems that the battery reporting of the TS0201 seems to be broken. Ich habe schon sehr viel . The ones I have do update more frequent than every hour if the temperature difference is more than 0. I see a temperature and a humidity reported on the device page, which is in line with reality, but it seems to have no updated in over an hour. The existing upstream quirk in zha-device-handlers (zhaquirks/tuya/ts0201. sensors, and some of them do not seem to update often enough. There are: 1x The humidity gave an average offset of 5%, which is a little more than the sensor is advertised, so calibration of the humidity was needed. eczbzr bpng nkntrtvx fit wkevfo
Ts0201 does not update frequently. You are on the “name”: “attr/swversion” attribute, this ...